DDG 51 CLASS ADVISORY NR 02-93 AN-SPY-1D HIGH VOLTAGE POWER SUPPLY POTENTIAL SAFETY HAZARD REF/A/DOC/NAVSEA/-// REF/B/DOC/NAVSEA/-// REF/C/DOC/NAVSEA/-// NARR/REF A IS TECHNICAL MANUAL, NAVSEA SW279-CR-AEG-090/OT- 146/SPY-1D. REF B IS MRC 4560/R07-92. REF C IS NAVSEA S9AAO-AB- GOS-010, GEN SPECS FOR OVERHAUL OF SURFACE SHIPS, SECTION 602H.// RMKS/1. THIS ADVISORY IS INTENDED TO ALERT ALL PERSONNEL INVOLVED WITH THE OPERATION AND MAINTENANCE OF SUBJECT EQUIPMENT TO A POTENTIAL SAFETY HAZARD WITH THE NEW HIGH VOLTAGE POWER SUPPLY INTERLOCKS IN THE AN/SPY-1D SYSTEMS. THIS ADVISORY APPLIES TO DDG 51 AND FOLLOW. 2. BACKGROUND. THE RIGHT BARRIER SCREEN AND CABLE ENTRY PANEL HAVE CHEATABLE INTERLOCKS WHICH, IF BYPASSED, ALLOW HIGH VOLTAGE TO EXIST WITHIN THE POWER SUPPLY. THIS PROBLEM WILL BE CORRECTED BY THE INSTALLATION OF ORDALT (O/A) 20213, WHICH WILL REPLACE THE CHEATABLE INTERLOCK WITH A NON-CHEATABLE INTERLOCK. ANTICIPATE THIS O/A WILL BE AVAILABLE BY JUNE 1994. 3. ACTION. A. PRIOR TO PERFORMING MAINTENANCE ON THE HIGH VOLTAGE POWER SUPPLY IAW REFS A AND B, ENSURE THAT THE FOLLOWING STEPS HAVE BEEN TAKEN: (1) THE GROUNDING ROD IS CONNECTED TO THE "GROUND HERE" POINT AT ALL TIMES WHEN THE BARRIER SCREEN DOOR IS OPEN. (2) HIGH VOLTAGE POWER SUPPLIES ARE IN LOCAL CONTROL BEFORE OPENING THE CABLE ENTRY PANEL. (3) DISCHARGE AND GROUND ALL HIGH VOLTAGE CAPACITORS AND EXPOSED HIGH VOLTAGE TERMINALS. PERFORM THIS STEP SEVERAL TIMES TO ASSURE THAT ALL HIGH VOLTAGE TERMINATIONS HAVE BEEN COMPLETELY DISCHARGED. (4) DO NOT BYPASS THE BARRIER SCREEN DOOR INTERLOCK (S7) OR THE CABLE ENTRY PANEL INTERLOCK (S6) IN THE HIGH VOLTAGE POWER SUPPLY. B. ON THE FRONT PANEL OF EACH POWER SUPPLY INSTALL A WARNING SIGN FABRICATED IAW REF C READING AS FOLLOWS: WARNING HIGH VOLTAGE - DO NOT BYPASS BARRIER INTERLOCK S-7 OR PANEL INTERLOCK S-6 4. FOR COMNAVSURFLANT - REQUEST DDG 51 AND DDG 52 BE TASKED TO ADHERE TO THE ABOVE SAFETY PRECAUTIONS. 5. FOR SUPSHIP PASCAGOULA/BATH - REQUEST SHIPYARD PERSONNEL AND DDG 53 AND FOLLOW SHIP PRECOMUNITS BE NOTIFIED TO ADHERE TO THE ABOVE SAFETY PRECAUTIONS. 6. FOR NSWC PHD - SINCE ORDALT 20213 IS NOT IMMEDIATELY AVAILABLE, INCORPORATE THE FOLLOWING SAFETY PRECAUTION INTO APPLICABLE MRC'S (Q-8, Q-17, 18M-4, AND 60M-10) OF REF B PMS - "DO NOT BYPASS BARRIER INTERLOCK S-7 OR PANEL INTERLOCK S-6". 7. THIS ADVISORY HAS NO IMPACT ON EOSS, CMMP OR TECHNICAL DOCUMENTATION. IT WILL BE CANCELLED UPON COMPLETION OF ORDALT 20213 IN ALL APPLICABLE SHIPS. 8. POC IS MR N. S. SMITHSON, PMS400F511, DSN: 332-5981 OR COMM (703) 602-5981. NSWC PHD TECHNICAL POC IS MR J. CHUNG, CODE 4C11, DSN: 551-8689 OR COMM (805) 982-8689.//